로그인 | 등록하다
产品中心
홈페이지 > 제품 > Vacuum circuit Breaker > Indoor Vacuum circuit Breaker > AP-ZN85-40.5 Indoor Handcart VCB

AP-ZN85-40.5 Indoor Handcart VCB

    AP-ZN85-40.5 Indoor Handcart VCB

    Vacuum circuit breaker manufacturers As a source vacuum circuit breaker manufacturer in Wenzhou, China, we ensure top quality and low prices by producing all key parts in-house, including operating mechanisms and vacuum interrupters. We offer OEM services and provide reliable XIHARI test reports for your confidence.accumsan id imperdiet et, porttitor at sem.
  • 공유하다:
  • 문의하기 문의
  • 이메일:ansel@apexe.cc

AP-ZN85-40.5 Indoor Handcart Vacuum Circuit Breaker

Product introduction

AP-ZN85-40.5ZN85-40.5/T(3AV3)indoor handcar vacuum circuit breaker is suitable for three-phase,Ac50Hzwith 40.5KV rated voltage. It can be used for industrial and mining enterprises, power plants and substations as load current and overload current fault current, and is suitable for the occasion with frequent operation. The circuit breaker adopts an upper and lower arrangement structure to effectively reduce the depth of the circuit breaker. It adopts the composite insulation structure, the three-phase arc extinguishing chamber and the associated electrified body. Separated by three independent epoxy insulation cases, the circuit breaker meets the air distance and creepage requirements under normal operating conditions after the composite insulation structure and it effectively reduces the size of the circuit breaker. The main conductive circuit vacuum interrupter and the dynamic and static conduclive  conneclion are installed in the insulation tube, so that the phase to phase distance is only 300mm.The main circuit electrical connections are all fixed connections with high reliability.

 

Applying ambient Conditions

1.Ambient temperature:-30~+40.

2.Relative humidity :the average humidity of a day should be no more than95%.The average humidity of a month should be no more than90%.

3.Earthquake intensity : not exceed8 degrees.

4.Saturated vapor pressure :the average pressure of a day should be no more than 2.2kPa;the average pressure o fa month should beno more than1.8Kpa.

5.The height above sea level:1000 m(Except special requirements).

6.It should be installed in the places without fire, explosion ,serious filth, and chemical erosion and violent vibration.


No.ItemUnitDate
1Rated voltageKV40.5
2Rated currentA1250 | 1600 | 2000
3Rated short circuit breaking currentKA25 | 31.5 | 25 | 31.5
4Rated dynamic stability current (peak)KA63 | 80 | 63 | 80
54S thermal stability currentKA25 | 31.5 | 25 | 31.5
6Rated short circuit closing current (peak)KA63 | 80 | 63 | 80
7Rated short circuit current breaking timeTimes20
8Rated operating sequence
O-0.3s-CO-180s-CO
9Rated insulation levelKV95
1 min power frequency withstand
Lightning impulse withstand voltage
185
10Mechanical lifeTimes10000
11Rated single capacitor bank opening and closing currentA630
12Rated back-to-back capacitor bank currentA400
13Rated voltage of energy storage motorVAC, DC:110; 220
14Rated power of energy storage motorW≤230
15Energy storage time of energy storage motorS≤15
16Rated voltage of opening and closing coilVDC:110; 220
17Rated current of opening and closing coilA1.05(110V) 0.96(220V)
18Contact strokemm20±2
19Contact contact strokemm7.5±1.5
20Three-phase opening, closing phase asynchronousms≤2
21Contact closing bounce timems≤3
22The main circuit resistance (not include the contact arm)μΩ≤40



온라인 메시지

유효한 이메일 주소를 입력해 주세요